mrcImageMultiCTFDetermination
From EosPedia
mrcImageMultiCTFDetermination is Eos's Command that performs determination of CTF from multiple images of the same field of view.
Contents
List of option
Main option
| Option | Essential/Optional | Description | Default |
|---|---|---|---|
| -i | Essential | Input: ASCII | NULL |
| -o | Optional | Output Optimum | stdout |
| -oP | Optional | Output Distribution: mrcImage | NULL |
| -kV | Optional | Acceleration voltage: [kV] | 200 |
| -Cs | Optional | Spherical aberration coefficient: [mm] | 1.7 |
| -AoverP | Optional | AoverP[A](minAoverP, maxAoverP, delAoverP) | (0.0, 1.0, 0.01) |
| -Rmax | Optional | Maximum spatial frequency: [/A] | 0.1 |
| -c | Optional | ConfigurationFile | NULL |
| -m | Optional | Mode | 0 |
| -h | Optional | Help |
-m details
| Value | Description |
|---|---|
| 0 |
-i format
filename minDef[A] maxDef[A] deltaDef[A]
. . . .
. . . .
. . . .
Execution example
Input file's data